Programming
Motor Programming continued
Notes on Motor Programming
There are a number of different modes
available for motor programming:
1. Forwards - Pause - Backwards
T. FORWARD = XXs
T. PAUSE = XXs
T. BACKWARDS = XXs
2. Forwards - Pause
T. FORWARD = XXs
T. PAUSE = XXs
T. BACKWARDS = S0
3. Forwards
T. FORWARD = XXs
T. PAUSE = S0
4. Pause - Backwards
T. FORWARD = S0
T. PAUSE = XXs
T. BACKWARDS = XXs
5. Backwards
T. FORWARD = S0
T. PAUSE = S0
T. BACKWARDS = XXs
The minimum pause time that can be
programmed between forward and backwards
is 2 seconds. The maximum time is 239
seconds.
Cylinder speed is programmed during cycle
programming. In this mode, each step can be
programmed with different values if desired.
B&C Stock Motor Assignments
9
Motor Number Forward Pause Reverse
1 16 4 16
2 4 16 4
3 5 115 5
14 0 0 1
15 1 0 0
Motor 1 - used for normal wash agitation.
Motor 2 - used for gentle wash agitation.
Motor 3 - used for soak formulas
Motor 14 - Used for Unroll cycles (reverse only)
Motor 15 - Used for Spin cycles (forward only)
Kommentare zu diesen Handbüchern